Fluoroplastic Self-Priming Pump
Fluoroplastic Self-Priming Pump

Fluoroplastic Self-Priming Pump

Product Introduction

FZB fluoroplastic self-priming pump for acids, alkalis, and solvents. F46-lined wetted parts, reliable priming, and custom factory supply.

Product Information

Rated flow:
30–45 m³/h
Rated head:
25–30 meters
Motor power:
7.5 kW
Rated speed:
2,900 rpm
Inlet × outlet:
DN80 × DN65
facebook
line
Whatsapp
Pinterest
Tumblr
Linkedin

The FZB fluoroplastic self-priming pump transfers corrosive liquids from tanks, pits, drums, and other low-level sources. Its self-priming structure helps lift liquid into the pump after the casing is filled for the first start. Therefore, it is a practical choice when the liquid level is below the pump inlet.

Jingjiang Xiangsu Pump Industry Co., Ltd. manufactures FZB pumps for chemical plants and industrial fluid systems. We match the pump size, lining, seal, motor, and base to each duty point. As a result, customers receive a pump that fits both the liquid and the process.

 

Representative Technical Parameters

The pictured unit has a visible DN65 discharge connection. Therefore, its structure is consistent with an 80FZB(L)-class configuration.

Item Typical Specification
Reference model 80FZB(L)
Pump type Horizontal self-priming centrifugal pump
Rated flow 30–45 m³/h
Rated head 25–30 m
Motor power 7.5 kW
Rated speed 2,900 rpm
Inlet × outlet DN80 × DN65
Maximum suction height About 4 m
Standard liquid temperature Below 90°C
Wetted material F46 fluoroplastic lining
Shaft seal Mechanical seal
Installation Base-mounted with motor and coupling guard

These values are typical reference data. Actual performance depends on liquid density, viscosity, temperature, vapor pressure, suction pipe design, and motor frequency. Therefore, the final model should be selected from the required flow and head.

 

619250edb3b9f76b72a104426e8e0fce.jpg

 

Strong Protection Against Corrosion

The pump uses a strong metal outer casing with a fluoroplastic lining on the wetted surfaces. This design combines the strength of metal with the chemical resistance of fluoroplastic.

F46 is suitable for many acids, alkalis, salts, and organic solvents. In addition, PVDF or reinforced polypropylene options may be available for some working conditions. However, material compatibility must always be checked against the liquid concentration and temperature.

Typical wetted parts include:

  • Fluoroplastic-lined pump casing
  • Fluoroplastic impeller
  • Corrosion-resistant pump cover
  • Selected mechanical seal faces
  • PTFE, FKM, or other suitable gaskets

 

Reliable Self-Priming Operation

The FZB pump uses a liquid recirculation chamber to remove air from the suction line. First, the pump casing must be filled with liquid. Then, after startup, the rotating impeller mixes the stored liquid with air from the inlet pipe. The air is discharged, while the liquid stays in the casing. As a result, the pump creates suction and draws liquid into the system.

In many systems, the casing keeps enough liquid for the next start. Therefore, repeated filling may not be needed. However, if the pump has been drained or left unused for a long time, the operator should check and refill the casing before startup.

 

Main Product Benefits

  • Self-priming design for low-level tanks and pits
  • F46-lined wetted parts for corrosive liquids
  • No foot valve required in many installations
  • Strong base for stable operation
  • Mechanical seal selected for the working liquid
  • Flanged inlet and outlet for firm pipe connections
  • Coupling guard for safer operation
  • Simple access for inspection and service
  • Custom motor voltage and frequency options
  • Pump and motor supplied as one aligned unit

 

Fluorine-lined self-priming pump 3.jpg

 

Suitable Liquids and Industries

The FZB fluoroplastic self-priming pump is designed mainly for clean or lightly contaminated chemical liquids. Common media include diluted or concentrated acids, alkalis, salt solutions, pickling liquid, plating solution, and selected solvents.

Typical applications include:

  • Chemical production
  • Acid and alkali transfer
  • Tank unloading
  • Electroplating lines
  • Metal pickling systems
  • Pesticide production
  • Pharmaceutical processing
  • Electronics manufacturing
  • Waste liquid collection
  • Paper and textile plants

 

The standard pump is not intended for large solids or highly abrasive slurry. Therefore, a suction filter should be installed when particles may enter the pipe.

 

Installation and Startup

Install the pump on a firm, level foundation. Also, keep the suction pipe short and direct. Every suction joint must be airtight because even a small air leak can reduce priming performance.

Before the first start, fill the pump casing with liquid. Next, check the motor rotation and open the required valves. Never run the pump dry, since dry running can damage the mechanical seal and fluoroplastic parts.

For better results, reduce sharp bends in the suction pipe. In addition, keep the actual suction height within the selected pump limit. Hot liquids, dense fluids, and liquids with high vapor pressure may reduce the available suction height.

 

Manufacturer Support and Custom Supply

Jingjiang Xiangsu Pump Industry Co., Ltd. supports pump selection from inquiry to delivery. Our team reviews the fluid data and then recommends a suitable model, material, seal, and motor.

Available supply options include:

  • F46, PVDF, or selected plastic wetted parts
  • Different mechanical seal materials
  • Standard or explosion-proof motors
  • Custom voltage and frequency
  • Pump-only or complete base-mounted units
  • Matching inlet and outlet flanges
  • Factory performance inspection
  • Export packing and spare-parts supply

For an accurate quotation, please provide the liquid name, concentration, temperature, density, required flow, required head, suction height, motor voltage, and operating frequency.

 

Frequently Asked Questions

Does the pump need priming before startup?

Yes. Fill the casing before the first start or whenever the stored liquid has been lost.

Can the pump run without liquid?

No. Dry running can quickly damage the mechanical seal and internal parts.

Can it transfer sulfuric or hydrochloric acid?

F46 is compatible with many acid solutions. However, concentration, temperature, and impurities must be checked before model selection.

What affects the self-priming height?

Pipe length, air leaks, liquid temperature, density, viscosity, and installation height all affect priming performance.

Can the motor specification be customized?

Yes. Voltage, frequency, protection level, efficiency class, and explosion-proof options can be matched to the project.

Request a Pump Selection

Contact Jingjiang Xiangsu Pump Industry Co., Ltd. for fluoroplastic self-priming pump selection and pricing. Send us your operating data, and our team will prepare a suitable technical proposal for your chemical transfer system.